For Immediate Release:
Perry nuclear running with multiple inoperable safety systems 
Perry Event Report: LOW PRESSURE CORE SPRAY INOPERABLE
| 
| U.S. Nuclear Regulatory CommissionOperations Center
 Event Reports For5/24/2019 - 5/28/2019
 ** EVENT NUMBERS ** |  | 
 
| 
| Power Reactor | Event Number: 54085 |  
| Facility: PERRY Region: 3     State: OH
 Unit: [1] [] []
 RX Type: [1] GE-6
 NRC Notified By: DAVID DUESING
 HQ OPS Officer: CATY NOLAN
 | Notification Date: 05/24/2019 Notification Time: 13:09 [ET]
 Event Date: 05/24/2019
 Event Time: 07:30 [EDT]
 Last Update Date: 05/24/2019
 |  
| Emergency Class: NON EMERGENCY 10 CFR Section:
 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
 
 | Person (Organization): JAMNES CAMERON (R3DO)
 |  
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |  
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |  Event Text 
| LOW PRESSURE CORE SPRAY INOPERABLE 
 "At  0730 [EDT] on May 24, 2019, it was discovered that the Low-Pressure  Core Spray System was inoperable. At Perry, the Low-Pressure Core Spray  system is considered a single train system in Modes 1, 2, and 3;  therefore, this condition is being reported as an eight-hour,  non-emergency notification per 10 CFR 50.72(b)(3)(v). Inoperability of  the Low-Pressure Core Spray system was caused by Emergency Service Water  Pump A inoperability.
 
 "There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
 |  | 
 
 
Michael J. Keegan
mkeeganj@comcast.net